Fire detection and extinguishing
Also called Fire protection system, Engine fire detection, Fire extinguishing system, Fire bottles
Fire detection and extinguishing is the aircraft system that senses fire, overheat or smoke in engines, the APU, cargo holds, lavatories and wheel wells, and puts out or contains fire in the zones it protects. Detection warns the crew; fixed bottles fired from the flight deck discharge an extinguishing agent into the affected zone.
What it is
A fire on board leaves little time. The fire protection system exists to tell the crew quickly and reliably where a fire is, and to give them a way to put it out or hold it back until the aircraft is on the ground. It has two halves:
- Detection: sensors in each fire zone that trigger a warning on the flight deck, usually a master warning, a bell or chime, a lit fire handle and a message on ECAM or EICAS.
- Extinguishing: fixed bottles of agent piped to the engines, the APU and the cargo holds, fired by the crew, plus automatic extinguishers in lavatory waste bins and portable extinguishers in the cabin and on the flight deck.
What is protected, and how, is set by the certification rules in CS-25 and 14 CFR Part 25. The detail varies by type, so the crew follows its own manuals.
Detection
Engines and APU
Engines and the APU are watched by continuous detection loops: thin tubes or wires run around the hot parts of the nacelle. Two kinds are common.
- Gas-filled loops hold a gas that expands when heated, or gives off gas from a core material, closing a pressure switch at a set temperature. They respond to a general rise in temperature and to a local hot spot.
- Electrical loops use a core whose resistance falls sharply when heated, changing the signal that the control unit measures.
An engine normally has two independent loops. Most systems need both to sense the condition before giving a fire warning, which stops one faulty loop from causing a false alarm. If one loop fails, the system reverts to the other one alone. Some systems also give an overheat caution at a lower temperature than the fire warning.
Cargo holds and lavatories
Cargo holds and lavatories use smoke detectors, usually optical (a light beam scattered by smoke) or ionisation types. Cargo detectors often sample air from several points, and a warning may need two detectors to agree. Some types also detect overheat in the main wheel bays and electronic bays. A wheel well fire warning usually comes from heat sensors in the bay.
Testing
The crew tests detection from the flight deck before flight, typically with a single button or switch that checks the loops, the warnings and the bottle circuits. A failed test is checked against the minimum equipment list.
Extinguishing
| Zone | Typical detection | Typical extinguishing |
|---|---|---|
| Engine | Two continuous loops | Two shots per engine, from shared or dedicated bottles, fired by the crew |
| APU | Continuous loop | One bottle, fired by the crew or automatically on the ground |
| Cargo hold | Smoke detectors | Bottles fired by the crew: a quick discharge, then a slow metered flow |
| Lavatory | Smoke detector | Automatic extinguisher in the waste bin |
| Cabin and flight deck | Crew and passengers | Portable extinguishers (halon type and water) |
Fixed systems mostly use Halon 1301. It is stored as a liquid under nitrogen pressure and turns to gas when released. It stops combustion chemically and leaves no residue. A pyrotechnic cartridge, called a squib, breaks a seal to release it. Halon production is banned under international agreements on the ozone layer, and replacements are being introduced, first for lavatory and portable extinguishers. Existing stocks are recycled for aviation.
Cargo holds that the crew cannot reach in flight are built to contain a fire and are fitted with suppression that holds it down for a certified time. That time is one of the limits on how far from an aerodrome the aircraft may plan to be.
The fire handle
On an engine fire the crew uses the fire handle or switch for that engine. Pulling or turning it typically:
- closes the fuel shut-off valve (often called the LP or spar valve) so no more fuel reaches the engine;
- closes the hydraulic fluid shut-off valve and the bleed air valves;
- takes the engine generator off line;
- arms the extinguisher squibs.
The bottle is then discharged as a separate action. Isolation alone often stops a fire, because it cuts the fuel and air feeding it.
Worked example
A fictional twin-jet, "Example 123", gets an engine fire warning during climb at 1,800 ft. The crew:
- Flies the aircraft first and reaches the operator's minimum height for non-normal action.
- Confirms which engine has the warning, with both pilots checking before anything is moved.
- Brings the thrust lever of that engine to idle and shuts the engine down with the master or fuel control switch.
- Pulls the fire handle of that engine and discharges the first bottle.
- Waits the time in the checklist. If the warning stays on, it discharges the second bottle.
- Declares MAYDAY and lands at the nearest suitable aerodrome, even if the warning has gone out.
The wait between shots is type-specific. Operators publish their own values, typically some tens of seconds.
Common mistakes
The serious errors are acting on the wrong engine, rushing memory items at low height, and treating a warning that goes out as the end of the problem. A warning that comes back, a smell of smoke or a fire seen from the cabin all mean the fire may still be burning. Spurious warnings do happen, but the crew treats every one as real until it is proven otherwise on the ground.
Frequently asked questions
Why do engines have two detection loops?
So that one failed or damaged loop cannot cause a false fire warning or hide a real one. Most systems need both loops to agree before giving a warning, and switch to the remaining loop if one fails.
Does pulling the fire handle discharge the bottle?
Not on most types. Pulling or turning the handle isolates the engine and arms the bottles; the agent is discharged by a separate action, such as turning the handle or pressing a discharge button.
How long does a cargo fire suppression system last?
Long enough to reach a suitable aerodrome on the routes the aircraft is approved for. The certified duration varies by type and is a limit for extended diversion time operations.
What does the crew do if the fire warning goes out after the first bottle?
Follow the checklist. The engine stays shut down and the second bottle is kept for a fire that comes back, and the crew lands at the nearest suitable aerodrome.
Related terms
Sources
- EASA CS-25 and 14 CFR Part 25: powerplant fire protection, fire detector and extinguishing systems, cargo compartment classification
- FAA Aviation Maintenance Technician Handbook, Airframe: fire protection systems
- Manufacturer flight crew operating manuals: fire protection (generic)