Air conditioning packs
Also called Packs, Air cycle machine, Pack
Air conditioning packs are the units that turn hot, high-pressure bleed air into cool, dry air for the cabin and flight deck. Each pack cools the air through heat exchangers and an air cycle machine, and the conditioned air also pressurises the fuselage. Most airliners have two packs, and one can usually keep the aircraft habitable on its own.
What it is
An air conditioning pack, usually just called a pack, is a self-contained unit that takes hot compressed air and delivers cool, dry air at the right temperature and flow. Packs are the heart of the aircraft's environmental control system. They keep the cabin and flight deck comfortable, cool the avionics on many types, and supply the air that pressurises the fuselage.
On most aircraft the packs sit in the lower fuselage near the wing root, with ram air inlets and outlets on the belly. A typical twin-engine airliner has two packs, one fed mainly from each side. Larger aircraft may have more.
Where the air comes from
The conventional source is bleed air, taken from the engine compressors through the bleed air system. On the ground, or when the engines are not available, the APU can supply bleed air instead, and many aircraft can also be connected to a ground air unit.
Bleed air reaches the pack hot and at high pressure, far too hot to put into the cabin. A pack flow control valve at the entry to each pack opens, closes and sets how much air goes through. The flow it allows can usually be selected low, normal or high depending on the number of passengers and the need to save fuel.
Some newer designs, such as the Boeing 787, do not use engine bleed for the packs. Electric compressors take outside air and pressurise it, and the pack then cools it in a similar way.
How a pack cools the air
Most packs use the air cycle: they cool air by making it do work.
- Primary heat exchanger. The hot bleed air passes through a heat exchanger cooled by outside ram air, and loses part of its heat.
- Compressor. The air is compressed again by the compressor of the air cycle machine (ACM). This raises its temperature and pressure.
- Secondary (main) heat exchanger. The hotter, higher-pressure air is cooled again by ram air. Because it is hotter than before, it gives up more heat.
- Water extraction. Moisture is removed so the air delivered to the cabin is dry and does not freeze in the next stage.
- Turbine. The air expands through the ACM turbine. Expansion drops its temperature sharply, often well below freezing. The turbine also drives the compressor and a fan that pulls ram air through the heat exchangers on the ground.
The cold air leaves the pack and flows to a mixer unit, where it mixes with filtered cabin air drawn back by recirculation fans. Small amounts of hot bleed air, called trim air, are then added zone by zone so the flight deck and different parts of the cabin each get the temperature selected.
Temperature control
Each pack has a controller that adjusts valves to meet the temperature demand from the zones. Crews select temperatures on the overhead panel and cabin crew may adjust some zones. If a pack controller fails, a backup mode often keeps the pack working with reduced accuracy.
| Component | Job |
|---|---|
| Pack flow control valve | Starts, stops and regulates flow into the pack |
| Heat exchangers | Remove heat using outside ram air |
| Air cycle machine | Compresses, then expands the air to cool it |
| Water separator | Removes moisture before the turbine |
| Mixer unit | Mixes pack air with recirculated cabin air |
| Trim air valves | Add hot air to fine-tune each zone |
Packs and performance
Bleed air is not free. Each pack takes energy from the engines, which raises fuel burn and reduces the thrust available for a given engine setting. That is why:
- Packs-off or APU-bleed take-offs may be used at performance-limited airports, where permitted, to gain a little in take-off performance.
- Pack flow low saves fuel when the cabin is lightly loaded.
- Engine anti-ice and wing anti-ice also take bleed air, so in icing conditions there is less margin, and some procedures change pack settings to suit (engine and wing anti-ice).
Abnormal situations
Pack overheat
If the air temperature at the compressor outlet or pack outlet goes too high, the pack shuts down or the crew is asked to switch it off. Common causes are a blocked ram air inlet, a failing ACM or a valve fault. Many procedures allow a restart after the pack has cooled.
One pack inoperative
The remaining pack can usually maintain pressurisation and a reasonable cabin temperature on its own. Dispatch with one pack inoperative is often allowed under the minimum equipment list, typically with a maximum altitude limit and other conditions set by the operator.
Both packs lost
Without both packs no conditioned air enters the fuselage, so the cabin slowly depressurises through normal leakage and the outflow valve. Crews follow the type's procedure, which usually leads to a descent and, on many types, the use of ram air for ventilation once at a safe altitude.
Smoke and fumes
Smoke procedures often isolate one air source after another to find where the smoke comes from. Packs and the APU bleed are common suspects, so knowing which pack feeds which part of the aircraft helps.
Common mistakes
Typical errors include forgetting to switch packs back on after a packs-off take-off, which leads to a pressurisation warning in the climb, and starting a pack too early from the APU while the APU is also needed for engine start. On the ground in hot weather, running the packs without enough airflow can cause repeated pack overheats. Follow the after-take-off and APU procedures for your type closely.
Frequently asked questions
Why do some take-offs use packs off?
Each pack takes bleed air from the engines, which costs thrust. Switching the packs off, or supplying them from the APU, can give a small performance gain at a limiting airport. The aircraft flight manual and operator procedures say when it is allowed.
Can an aircraft fly with one pack inoperative?
Usually yes, under the minimum equipment list, often with limits on maximum altitude or other conditions. The exact limits are type-specific and published in the operator's MEL.
Is cabin air just recirculated?
Partly. On most airliners about half the cabin air is filtered and recirculated, and the rest is fresh air from the packs. The fresh air keeps the cabin pressurised and replaces what flows out through the outflow valve.
Why does the cabin fill with mist on a hot day?
Very cold pack air meets warm, humid cabin air and the moisture condenses into a visible fog. It is harmless and clears as the cabin cools.
Related terms
Sources
- FAA Aviation Maintenance Technician Handbook, Airframe, chapter 16: cabin environmental control systems
- EASA CS-25: Certification Specifications for Large Aeroplanes, ventilation and air conditioning
- FAA Advisory Circular 25-20: pressurization, ventilation and oxygen systems