Battery and static inverter

Also called Aircraft battery, Main battery, Static inverter, Standby power, Emergency electrical power

Updated 25/11/20264 min read
In short

The aircraft battery is the store of DC electrical power that starts the APU, keeps essential systems alive when every generator is lost and powers the aircraft on the ground before an engine runs. The static inverter is a solid-state unit that turns battery DC into AC, so that a few essential AC instruments and systems keep working on battery power alone.

Battery outputNominal 24–28 V DC
Inverter output115 V AC, 400 Hz
Common chemistriesNiCd, lead-acid, Li-ion

What it is

An airliner normally gets its electrical power from engine-driven generators, which make alternating current (AC), and from transformer-rectifier units, which turn part of that AC into direct current (DC). Two components sit underneath this normal system and only come to the front when it is missing:

  • The battery stores DC energy. It is the first source of power when the aircraft is cold and dark, the source that starts the APU on most types, and the last source left if every generator is lost.
  • The static inverter takes DC from the battery and produces AC. "Static" means it has no moving parts: it is electronic, unlike the old rotary inverters that used a DC motor to drive a small AC generator.

Together they form the backbone of the emergency electrical system. Where they connect, and what they feed, is described in the wider electrical system article.

The battery

Most transport aircraft carry one or two main batteries of a nominal 24 V, which read around 28 V on charge. Some types have a separate APU battery. The chemistry varies by age and design:

ChemistryTypical usePoints to know
Nickel-cadmium (NiCd)Many jets and turbopropsHigh current for starts, needs temperature monitoring
Lead-acid (sealed)Smaller aircraft, some airlinersSimple, heavier for its capacity
Lithium-ionSome modern aircraftLight and powerful, strict protection against thermal runaway

A battery charger, fed from the AC system, keeps the battery topped up in flight. The flight deck usually shows battery voltage and, on many types, charge current or a battery fault message. A battery that keeps drawing a high charge current long after start, or that runs hot, is a warning sign: some aircraft monitor this and isolate the battery automatically.

Lithium-ion main batteries brought new certification conditions after in-service events with an early installation, which is why lithium batteries on aircraft are tested and installed to dedicated guidance. Do not confuse these fixed installations with lithium battery fires in passenger devices, which are a cabin issue.

The static inverter

Several items that a crew needs in an emergency run on AC: some flight instruments, part of the avionics, certain fuel or hydraulic components, and on some types a standby radio or display. The inverter keeps these alive from the battery. It typically delivers single-phase 115 V AC at 400 Hz, the same frequency as the main system, to an essential or standby AC bus.

Its output is small compared with a generator. That is deliberate: it is sized for a short list of essential users, not for galleys, cabin lighting or windshield heating. When the system switches to battery and inverter power, everything else is shed automatically.

The inverter is normally idle and only powers its bus when the normal AC source is lost. Some types run it during the battery check before flight so the crew can confirm it works.

When they take over

The classic scenario is the loss of all AC generation in flight, for example a double generator failure on a twin with the APU unavailable.

  1. The normal AC buses lose power.
  2. The battery automatically connects to the essential DC bus (sometimes called the hot battery or battery bus).
  3. The static inverter starts and powers the essential or standby AC bus.
  4. The crew sees the electrical emergency configuration: a reduced set of instruments, one radio, essential lighting.
  5. Depending on the type, a ram air turbine deploys and takes over essential power, or the crew starts the APU, or both. If neither is available, the battery is all there is, and its endurance becomes a planning figure.

A worked example on a fictional twin-jet: both generators drop offline at FL350 and the APU will not start until lower altitude. The battery and inverter power the captain's display, one VHF radio and the standby instruments. The checklist asks the crew to shed non-essential loads, descend, start the APU and land at the nearest suitable aerodrome. The time shown in the flight manual for battery-only operation, not a guess, decides how urgent that landing is.

Remember: the battery-only time in the manual assumes the loads the procedure leaves on. Every extra item switched back on shortens it.
Learn it properlyFlight Operations trackShort units by airline pilots and a quiz at the end of each module. Your progress is saved.See the track

On the ground

The battery is often the first switch of the day. Before external power or the APU is on, it supplies a minimal set of buses for the preliminary checks, lighting and communications. Operators publish a minimum voltage for the battery check before APU start; below it, the APU start may fail and the battery may not be fit for flight. Leaving the battery on with no other source connected will flatten it, which is a familiar cause of a delayed first departure.

Common mistakes

  • Assuming the RAT or APU will always arrive and not knowing the battery-only endurance of the type.
  • Switching loads back on during an electrical emergency to "get the screens back", which drains the battery faster.
  • Treating a battery fault or high charge current message as a nuisance and continuing without checking the MEL.
  • Not knowing which instruments and radios sit on the inverter's bus, so the failed configuration comes as a surprise.

The fix for all of them is the same: learn the emergency electrical configuration of your type before you need it, including what you keep and for how long.

Frequently asked questions

How long will the battery last if all generators fail?

It depends on the type, the battery fitted and the load. The aircraft flight manual gives the time, and the abnormal procedure sheds load to stretch it. On many airliners a RAT or the APU takes over long before the battery is flat.

Why does the aircraft need an inverter if it already has AC generators?

Because the generators are exactly what has been lost when the inverter matters. The battery stores only DC, so the inverter is the one way to keep essential AC users running from it.

Why is battery voltage checked before APU start?

A low voltage means a weak or discharged battery that may not start the APU and may not support the essential buses in an emergency. Operators publish a minimum value for the check.

Do I need to know the exact bus layout?

For your own type, yes: which buses the battery and inverter feed decides which instruments, radios and systems you keep after a total generator failure. The general principle is the same on most aircraft.