Electrical system
Also called Aircraft electrical system, Electrical power system, AC and DC power
An airliner's electrical system makes, converts and distributes the power that runs its avionics, flight controls, lighting, galleys and many other systems. Engine-driven generators typically supply 115 V AC at 400 Hz, transformer rectifier units turn part of it into 28 V DC, and batteries, the APU and a ram air turbine keep essential equipment powered when the normal sources fail.
What it is
The electrical system is the network that makes power on board and sends it where it is needed. On a modern transport aircraft almost everything depends on it: displays, flight management, radios, fuel pumps, fly-by-wire computers, anti-ice heaters, lighting and the cabin. A total loss of electrical power is therefore one of the most serious system failures a crew can face, and the architecture is built so that it is very unlikely.
Most transport-category aircraft use two kinds of power:
- Alternating current (AC), typically 115 V at 400 Hz, three-phase, for heavy loads such as motors, heaters and galleys.
- Direct current (DC), typically 28 V, for avionics, control circuits, relays and anything that must run from the battery.
Some newer designs use variable-frequency generators and higher distribution voltages to save weight. The principles below still apply.
Power sources
| Source | What it gives | When it is used |
|---|---|---|
| Engine generator | AC, main supply | Normal flight, one or more per engine |
| APU generator | AC | On the ground, and as a backup in flight |
| Ground power unit | AC | At the gate, engines and APU off |
| Batteries | DC | Start-up, APU start, emergency supply |
| Ram air turbine | AC or hydraulic power, or both | Loss of all main power in flight |
| Static inverter | Small AC supply from DC | Emergency, when only batteries remain |
The classic engine generator is an integrated drive generator (IDG). The engine gearbox turns at a speed that changes with thrust, but the generator must turn at a constant speed to hold 400 Hz. A constant speed drive (CSD) inside the IDG does that, using its own oil system. If the drive overheats or loses oil pressure, the crew can disconnect it from the gearbox. On most types this disconnect cannot be reset in flight.
A variable frequency generator (VFG) skips the constant speed drive. Frequency then varies with engine speed, and the loads are designed to accept it. The unit is simpler and lighter.
Each generator has a generator control unit (GCU). It regulates voltage and frequency, and it trips the generator offline if it sees a fault such as over-voltage, under-frequency or a short circuit.
Distribution: buses
Power is distributed through buses, which are bars or circuits that collect power from a source and feed a group of users. A typical twin-engine layout looks like this:
- Each engine generator feeds its own AC bus, and the two sides normally run separately.
- Transformer rectifier units (TRUs) take AC from those buses and turn it into 28 V DC for the DC buses.
- Essential or emergency buses carry the equipment needed to fly, navigate and talk. They can be fed from several sources, down to the battery and the static inverter.
- A hot battery bus is connected straight to the battery and stays live even with the aircraft "off", for items such as fire extinguisher squibs and some clocks.
If one generator fails, bus tie breakers (BTBs) close so the remaining generator, or the APU, can feed both sides. The logic is automatic. It also stops two unsynchronised AC sources from being connected to the same bus.
When fewer sources are available than the full load needs, the system sheds load. Galleys and cabin power go first, then other non-essential items, so the essential buses stay powered.
Degraded configurations
Manufacturers design the system so that the aircraft can lose sources one after the other and still keep flying:
- One generator lost: the other generator, or the APU, takes over through the bus ties. Most crews notice only a caution and some galley shedding.
- All engine generators lost: the APU generator, if it is running or can be started, powers the main buses.
- All main AC lost: the ram air turbine deploys, automatically on most types, and powers the essential buses. On some types it also drives a hydraulic pump. See Ram air turbine.
- Battery only: the batteries feed the essential DC buses and, through a static inverter, a small AC bus. Many displays and systems are lost and the time available is limited.
Worked example
A twin-engine aircraft is in cruise when the left IDG shows a low oil pressure caution. The checklist calls for an IDG disconnect. The left generator drops offline, the bus tie closes and the right generator now feeds both AC buses. The galley sheds. The crew starts the APU, if the type and altitude allow it, and connects its generator to the left side. This restores two sources, and the galleys may come back.
The crew then considers the situation as a whole. The flight is now one failure away from losing another main source. On an ETOPS flight, the operator's procedures set what that means for the diversion decision. The disconnected IDG also affects the next dispatch under the minimum equipment list.
What pilots do
- On the ground: check battery voltage before start, confirm external power or the APU is supplying the buses, and know which items are powered before the engines are running.
- In flight: monitor the electrical page when a caution appears, read the source and bus status before acting, and follow the checklist rather than resetting breakers at random.
- Circuit breakers: many operators allow only one reset of a tripped breaker, and only for items needed for the flight. Never reset a fuel pump breaker in flight unless the procedures say so.
Common mistakes
Common errors include disconnecting the wrong IDG, starting the APU without checking the altitude and speed limits for its start, and pulling or resetting breakers without reference to the procedures. Another is forgetting that the battery alone has a limited endurance and treating a battery-only state as stable when it is not.
Frequently asked questions
Why do aircraft use 400 Hz instead of 50 or 60 Hz?
At a higher frequency, transformers, motors and generators can be smaller and lighter for the same power. The penalty is higher losses over long cables, which does not matter much inside an aircraft.
Can I reconnect an IDG after disconnecting it?
On most types, not in flight. The disconnect is mechanical and is normally reset only on the ground by maintenance, so crews disconnect only when the checklist calls for it.
How long does the main battery last on its own?
It depends on the type and the load. Certification requires the battery to power essential equipment for a defined period after a total generator loss, and manufacturers publish their own figures in the flight crew manuals.
Why is the galley the first thing to lose power?
Galleys and cabin loads draw a lot of power and are not needed to fly. Automatic load shedding cuts them first so the remaining generators can carry the systems that are.