Skip to content
Aircraft & systemsSafetyFlight operations

Cargo smoke detection

Also called Cargo fire detection, Cargo hold smoke detection, Cargo compartment fire protection

Updated 24/11/20264 min read
In short

Cargo smoke detection is the system that senses smoke in an aircraft's cargo holds and warns the flight crew. On most airliners it works with a built-in extinguishing system, so the crew can discharge an agent into the hold and keep a fire suppressed while the aircraft diverts to the nearest suitable airport.

Warning required within1 minute of fire start
Usual agentHalon 1301
Typical airliner holdClass C

What it is

The cargo holds of an airliner are out of sight and out of reach in flight. A fire there could grow for a long time without anyone noticing, so certification rules require holds to have a way to detect smoke or fire and, on most transport aircraft, a way to control it. Cargo smoke detection is the part that senses smoke and warns the crew. It is usually paired with a fixed extinguishing system and with controls for ventilation and heating in the hold.

The system is part of the wider fire detection and extinguishing on the aircraft, alongside engine, APU, wheel well and lavatory smoke detection.

Cargo compartment classes

CS-25 and the FAA's Part 25 group cargo compartments into classes, according to how a fire would be detected and controlled.

ClassMain ideaTypical use
ACrew can easily see and reach a fireSmall holds next to the flight deck
BCrew can reach any part of the hold in flight with a hand extinguisherSome cabin-level compartments
CNot accessible; needs detection, built-in suppression and smoke exclusionLower holds of most passenger airliners
EFreighter main deck; fire controlled by shutting off ventilationCargo aircraft

Class D, which relied on starving a fire of oxygen, has been removed from the certification codes, and existing Class D holds on passenger aircraft were converted to Class C. The current rules also define Class F, a main-deck compartment with fire detection and a means to extinguish or control a fire without a crew member entering it.

For a Class C hold, the requirements include a separate approved smoke or fire detection system, a built-in extinguishing or suppression system controlled from the flight deck, a means to keep hazardous amounts of smoke and agent out of occupied areas, and control of ventilation so the agent stays effective.

How detection works

Most cargo holds use optical smoke detectors. Air from the hold passes through a chamber where a light source and a sensor are arranged so that smoke particles scatter light onto the sensor. Above a threshold, the detector signals smoke. Some installations draw air from the hold to the detectors through sampling pipes; others mount detectors in the ceiling of the hold.

Certification rules require the detection system to warn the crew within one minute after a fire starts. Typical design features are:

  • several detectors in each hold, often grouped in cavities in the ceiling,
  • two independent loops, with logic that needs both to agree before warning, to reduce false alarms,
  • a self-test from the flight deck and fault indications if a detector fails,
  • a warning that shows which hold (forward, aft or bulk) has smoke.

Extinguishing

The agent used in cargo holds today is normally Halon 1301, stored in pressurised bottles. A typical system has two stages:

  1. Knockdown. On crew command, one or more bottles discharge quickly into the affected hold to reach a high concentration.
  2. Suppression. Further bottles discharge slowly, or through a metering device, to keep the concentration above the level needed for a set time.

The suppression time is a certified figure for each aircraft. It matters for route planning, because it limits how far the aircraft may be from a suitable airport, including for ETOPS. Before discharge, the system closes the hold's ventilation and heating, so the agent is not blown out of the hold.

Production of Halon has stopped under international agreements, and replacement agents are being developed for new designs.

Learn it properlyFlight Operations trackShort units by airline pilots and a quiz at the end of each module. Your progress is saved.See the track

What pilots do

A cargo smoke warning is a serious emergency. The exact steps are in the manufacturer's procedures, and the common elements are:

  1. Fly the aircraft and confirm the warning on ECAM or EICAS.
  2. Discharge the agent into the affected hold, as the checklist directs. The system usually isolates ventilation automatically.
  3. Declare an emergency and land at the nearest suitable airport. See diversion decision-making.
  4. Watch for smoke in the cabin or flight deck, and be ready to use oxygen masks and the smoke and fumes procedures.
  5. Brief the cabin crew and plan the ground phase. Request fire services, and do not let the hold be opened before firefighters are ready.
Remember: a discharged agent buys time, not certainty. Treat the warning as a real fire until the hold has been opened on the ground.

Lithium batteries and dangerous goods

Fires involving lithium batteries can be hard to suppress with Halon and can reignite. This is one reason the carriage of batteries in holds is restricted, and why accurate dangerous goods information to the commander matters. See also lithium battery fires.

Common mistakes

Typical errors are delaying the discharge to "confirm" the fire, continuing to the destination because the warning went out after discharge, and forgetting that the suppression time is limited. Another is ignoring a detection fault on the ground; a hold without working detection is handled under the minimum equipment list and may not be used for cargo.

Frequently asked questions

Does the extinguisher put the fire out?

It suppresses it. Halon stops a surface fire from burning freely but may not extinguish a deep-seated fire or one fed by lithium batteries. That is why the procedure after a cargo fire warning always includes landing at the nearest suitable airport.

How long does the suppression last?

It depends on the installation. A first discharge knocks the fire down, and a second, slower discharge keeps the concentration up for a period that is certified for the aircraft and limits how far it can be from a suitable airport.

Are cargo smoke warnings often false?

False warnings do occur, for example from condensation, dust or humidity in the hold. Crews still treat every warning as real until the aircraft is on the ground and the hold has been inspected.

Why are there several detectors in each hold?

Redundancy and fewer false alarms. Many systems use two detection loops and need both to sense smoke before a warning, while still warning if one loop has failed.

Sources

  1. EASA CS-25: CS 25.855 and CS 25.857, cargo compartment classification
  2. EASA CS-25: CS 25.858, cargo or baggage compartment smoke or fire detection systems
  3. 14 CFR Part 25: 25.855, 25.857 and 25.858
  4. Manufacturer flight crew operating manuals: cargo smoke and fire protection
Spotted a mistake, or something missing?Suggest an edit