Cargo fire
Also called Cargo hold fire, Cargo compartment fire, Hold smoke
A cargo fire is a fire in a cargo or baggage compartment, usually signalled by a smoke warning rather than seen. In most airliners the crew cannot reach the hold, so the fire is suppressed with an extinguishing agent while the aircraft lands at the nearest suitable airport. Time, not the extinguisher, is what the crew is managing.
What it is
A cargo fire is any fire in a compartment that carries baggage, mail or freight. On a passenger aircraft these holds are normally below the cabin floor and cannot be entered in flight. The crew learns about the fire through cargo smoke detection, fights it with a fixed extinguishing system if the hold has one, and gets the aircraft on the ground.
Cargo fires are dangerous for three reasons. The fire is hidden, so its size and growth are unknown. It can burn through the floor, wiring or control runs before anyone sees flames. And the hold may contain dangerous goods or passenger baggage with lithium batteries, which can burn very hot and resist suppression.
Compartment classes
Large aeroplane certification rules sort cargo compartments into classes according to how a fire there is detected and controlled. The class decides what protection the hold must have.
| Class | Typical location | How a fire is handled |
|---|---|---|
| A | Small area next to the flight deck | Crew can see and reach a fire from their station |
| B | Accessible compartment, some combis | Crew member can reach any part with a hand extinguisher |
| C | Lower holds of most passenger jets | Smoke detection, built-in extinguishing system, ventilation controlled |
| E | Main deck of freighters | Smoke detection, ventilation and airflow shut off, crew stays out |
An older class, D, relied on starving the fire of oxygen in a sealed hold. Regulators found it inadequate: it was removed from the certification rules and existing Class D holds were converted, mostly to Class C. More recent rules added a Class F for some main-deck compartments, so the aircraft's own documents are the reference.
How suppression works
A Class C hold typically has two stages of extinguishing. When the crew discharges the system, a first bottle releases a large quantity of Halon 1301 quickly to knock the fire down. A second, slower discharge then keeps enough agent in the hold to stop it flaring up again. The total time the system can maintain that concentration is the certified suppression time, which varies between aircraft types and installations.
Halon works by interrupting the chemistry of combustion rather than cooling the fuel. It is very effective on flames but not always on a deep-seated fire in packed baggage, and it does not stop a lithium battery cell from overheating the cells around it. That is why the suppression time is treated as the time available to land, not as proof that the fire is out.
On a freighter main deck (Class E), there is usually no extinguishing agent. The procedure shuts off airflow to the compartment and, on many types, raises the cabin altitude so the reduced oxygen slows the fire. Crew oxygen and smoke protection are then essential.
What pilots do
The details are in the aircraft's checklist, but the sequence is broadly the same:
- Confirm the warning and identify the compartment.
- Discharge the extinguisher for that hold, or carry out the Class E procedure on a freighter.
- Declare an emergency with MAYDAY and state the nature of the problem.
- Divert to the nearest suitable airport. Do not wait to see whether the warning clears.
- Check the NOTOC, the written notification to the commander of any dangerous goods on board, and pass the details to ATC so firefighters know what to expect.
- Prepare the cabin for a possible evacuation, and consider smoke and fumes procedures if smoke reaches the cabin or flight deck.
- After landing, stop on the runway or taxiway where firefighters can reach the aircraft, keep the hold door closed and decide on evacuation with the firefighters' information.
Worked example
Examplair 123, a twin-engine jet in cruise over land, gets an aft cargo smoke warning. The crew discharges the aft hold extinguisher, and the warning goes out after a minute. The captain's first instinct is to continue to destination, 70 minutes away. The first officer points out that a suitable airport is 18 minutes away and the checklist says to land at the nearest suitable one. They declare MAYDAY, divert, and pass ATC the NOTOC entry: a small quantity of lithium-ion batteries in the aft hold. On the ground, firefighters find heat damage around a single bag. The agent had held the fire, but it had not gone out.
Planning for a cargo fire
Because the suppression time is limited, it sets how far from a suitable airport the aircraft may plan to fly. Long-range and ETOPS operations must show that, from any point on the route, the aircraft can reach an alternate within the certified suppression time with a margin. Operators also control which dangerous goods may go in which hold and in what quantity, so that a fire stays within what the protection can handle.
Common mistakes
The usual errors are waiting for the warning to clear before diverting, choosing a better-equipped airport much further away over a nearer suitable one, forgetting to give ATC the dangerous goods details, and opening the hold door on the ground before firefighters are ready. Another is assuming a false alarm because the warning came and went: from the flight deck, that cannot be known.
Frequently asked questions
Does discharging the cargo extinguisher put the fire out?
Not necessarily. Halon suppresses flames by interrupting the chemical reaction, and the system keeps a concentration in the hold for a certified time. A deep-seated fire, or a lithium battery fire, may keep smouldering or reignite, so the crew still lands as soon as possible.
Can a cargo smoke warning be false?
Yes. Condensation, dust or some cargo can trigger detectors. The crew cannot tell from the flight deck, so a warning is treated as a real fire until the aircraft is on the ground and firefighters have checked.
Should the hold be opened after landing?
Not by the crew or handlers. Opening the door lets oxygen in and can make a suppressed fire flare up. Rescue and firefighting services decide when and how to open it.
Why does the suppression time matter for route planning?
The aircraft must be able to reach a suitable airport before the agent concentration runs out. On long overwater or remote routes, and in ETOPS planning, the certified suppression time limits how far the aircraft can be from an alternate.
Related terms
Sources
- EASA CS-25: CS 25.855 and 25.857, cargo or baggage compartments and their classification
- FAA 14 CFR Part 25: sections 25.855, 25.857 and 25.858
- ICAO Annex 18 and Doc 9481, Emergency Response Guidance for Aircraft Incidents Involving Dangerous Goods