Oxygen systems
Also called Supplemental oxygen, Crew oxygen, Passenger oxygen, Oxygen masks, Quick-donning mask
Aircraft oxygen systems supply breathing oxygen to the crew and passengers when cabin pressure is lost or smoke fills the cabin. Pilots use quick-donning masks fed from high-pressure cylinders; passengers get drop-down masks, usually fed by chemical generators, and cabin crew carry portable bottles. The supply lasts long enough for an emergency descent to a safe altitude.
What it is
A pressurised cabin keeps people at a cabin altitude of a few thousand feet while the aircraft cruises much higher. If that pressure is lost, the air in the cabin quickly becomes as thin as the air outside, and hypoxia follows within seconds or minutes. The oxygen system bridges the gap. It keeps everyone conscious while the crew carries out an emergency descent to an altitude where the air can be breathed again.
There are usually three separate parts:
- Flight crew oxygen: high-pressure cylinders feeding a quick-donning mask at each flight deck seat.
- Passenger oxygen: drop-down masks above each seat row, in lavatories and at cabin crew stations, usually fed by chemical oxygen generators.
- Portable oxygen: small cylinders with masks for cabin crew moving about after a decompression and for first aid, and protective breathing equipment (PBE, a smoke hood) for fighting fires.
Flight crew oxygen
Each pilot has a mask stored in a box beside the seat. It must be put on with one hand and sealed within seconds; the rule for transport aircraft is within five seconds. Squeezing the harness grips inflates the harness, which then pulls the mask onto the face when released.
The regulator has three settings, though the names vary by type:
| Setting | What it gives | When it is used |
|---|---|---|
| Normal (diluter demand) | Oxygen mixed with cabin air, on inhalation only | Decompression with clean air |
| 100% | Pure oxygen on demand | Smoke or fumes, or by procedure |
| Emergency | Pure oxygen at slight overpressure | Smoke in the mask, and at very high cabin altitudes |
Most masks have a microphone and smoke goggles, either built in or separate. Crew oxygen comes from one or more cylinders in the lower fuselage. Pressure is shown on the flight deck, and the minimum for dispatch depends on the number of crew and the temperature, from a table in the operator's manual.
Rules also say when a pilot must wear the mask. Under 14 CFR 121.333, for example, if one pilot leaves the controls above FL250 the other must wear the mask. On larger aeroplanes with quick-donning masks, one pilot at the controls must wear the mask at all times above FL410 (above FL350 on smaller ones). EASA and other States have similar rules.
Passenger oxygen
Passenger masks drop automatically when the cabin altitude rises past a set value, typically about 14,000 ft, and the crew can also release them with a switch. Pulling a mask towards the face pulls a pin that starts the chemical generator above it. The generator burns a mixture based on sodium chlorate and gives off oxygen for a fixed time, typically 12 to 22 minutes depending on the type and the terrain on its routes. It gets very hot and smells of burning, which is normal. Some long-haul aircraft use a gaseous system instead, with cylinders, so the flow can last longer.
The duration of the passenger supply shapes the emergency descent. Over high terrain the aircraft may not be able to descend to 10,000 ft at once, and the company's escape routes are planned so the oxygen lasts until it can. See drift-down for the related engine-failure case.
The rules
ICAO Annex 6 sets the basic requirements in terms of cabin pressure. Supplemental oxygen is needed for crew, and for part of the passengers, for flight longer than 30 minutes with the cabin between 700 hPa and 620 hPa, roughly 10,000 ft and 13,000 ft. Below 620 hPa, above roughly 13,000 ft, everyone needs it for the whole time. A pressurised aeroplane flying above about 25,000 ft (376 hPa), or one that could not descend within four minutes to the 620 hPa level, must also carry at least a 10-minute supply for everyone in the passenger compartment. EASA and the FAA turn this into detailed tables by altitude and time.
Time of useful consciousness
Time of useful consciousness (TUC) is the time a person can still act sensibly without oxygen. It falls fast with altitude. Typical values for a resting person, from FAA Advisory Circular 61-107B (see also hypoxia):
| Altitude | TUC |
|---|---|
| FL250 | 3–5 minutes |
| FL300 | 1–2 minutes |
| FL350 | 30–60 seconds |
| FL400 | 15–20 seconds |
Rapid decompression and physical effort shorten these times, sometimes by half.
Worked example
A fictional twin-jet, registration X-ABCD, cruises at FL370 when the cabin altitude warning sounds and the cabin altitude climbs fast. The crew:
- Puts on the masks and selects 100%, then checks they can talk to each other.
- Checks the cabin altitude and rate, and confirms the decompression.
- Starts the emergency descent, with the speed brakes as the procedure says, and turns off the airway if required.
- Declares MAYDAY and sets 7700 if needed.
- Confirms the passenger masks have dropped, releasing them by switch if they have not.
- Levels off at 10,000 ft or the minimum safe altitude, whichever is higher, and plans a diversion.
The descent from FL370 to 10,000 ft takes a few minutes, well inside a typical generator's duration, but only if it starts at once.
Common mistakes
Typical errors are trying to diagnose the problem before putting on the mask, leaving the mask in normal mode in smoke, and checking the mask on the ground in a way that empties the cylinder below the dispatch minimum. Another is forgetting that the cabin crew need oxygen too: they sit or hold on and use the nearest mask before moving.
Frequently asked questions
Why do the passenger masks give so little flow at first?
Chemical generators produce a steady flow after a short start, and the bag does not have to inflate for oxygen to be flowing. Passengers are told to keep breathing normally through the mask.
Why should pilots select 100% or emergency on the mask in smoke?
In normal mode the mask mixes cabin air with oxygen, so smoke would be breathed too. At 100% the mask gives pure oxygen, and emergency adds slight overpressure that keeps smoke out of the mask and goggles.
Can the crew oxygen run out on a long flight?
The minimum quantity for dispatch is set from the crew number and the route, so that it covers a decompression and descent at the worst point. Each crew member's mask use, including checks, draws on the same supply.
Is it safe to use oil or hand cream near oxygen?
No. Oil and grease can ignite in high-pressure oxygen. Crews keep fittings and masks clean, and maintenance uses only approved materials on oxygen parts.
Related terms
Sources
- ICAO Annex 6, Part I: oxygen supply and supplemental oxygen requirements
- EASA Air OPS, CAT.IDE.A: supplemental oxygen for pressurised aeroplanes and flight crew quick-donning masks
- 14 CFR 121.329 and 121.333: supplemental oxygen requirements
- FAA Advisory Circular 61-107B: aircraft operations at altitudes above 25,000 ft MSL or Mach numbers greater than .75 (time of useful consciousness)
- 14 CFR 25.1447: equipment standards for oxygen dispensing units