Engine fuel control
Also called Fuel control unit, FCU, Hydromechanical unit, HMU, Fuel metering unit, FMU
Engine fuel control is the system that meters exactly how much fuel a turbine engine receives for the thrust the pilot or autothrust asks for. It keeps the engine inside its limits of speed and temperature and follows set acceleration and deceleration schedules so the engine does not surge, stall or flame out. On modern engines a FADEC computes the demand and a separate unit meters the fuel.
What it is
A turbine engine runs on a simple principle: more fuel, more energy in the turbine, more thrust. The difficult part is giving it the right amount at every moment. Too little and the flame goes out. Too much, or too quickly, and the compressor stalls or the turbine overheats. The engine fuel control is the system that solves that problem continuously, from start to shutdown.
It has two jobs:
- Decide how much fuel the engine should get, from the thrust lever, the air conditions and the engine's own state.
- Meter that exact flow to the fuel nozzles in the combustion chamber.
Older and modern designs
On older engines both jobs were done by one hydromechanical fuel control unit (FCU). Inside it, governors, cams, bellows and springs sensed the thrust lever angle, compressor speed, inlet pressure and temperature, and moved a metering valve. It worked well, but every schedule was cut into metal and could only be changed by changing parts.
On most modern engines the decision is taken by an electronic computer, the electronic engine control (EEC). When it has full authority over the engine with no mechanical back-up, the system is called FADEC. The metering is still done by hardware, a hydromechanical unit (HMU) or fuel metering unit (FMU), which receives electrical commands from the EEC and moves its metering valve to match.
| Function | Hydromechanical FCU | FADEC with HMU/FMU |
|---|---|---|
| Computes fuel demand | Cams, governors, bellows | EEC software |
| Meters fuel | Metering valve in the FCU | Metering valve in the HMU/FMU |
| Protects limits | Mechanical stops and schedules | Software limits on speed, temperature and pressure |
| Changes to schedules | New parts | New software, after certification |
The fuel path
Fuel leaves the aircraft fuel system and reaches the engine through a low-pressure pump, usually a filter and a fuel-oil heat exchanger that warms the fuel and cools the engine oil. A high-pressure pump then raises the pressure well above what the nozzles need. The metering valve lets the demanded flow through; the excess goes back to the pump inlet through a bypass valve. Downstream of the metering valve sits the high-pressure shut-off valve, opened and closed by the fuel lever or engine master switch. The metered fuel then flows to the nozzles, and a flow meter sends the value to the cockpit fuel flow indication.
Schedules and protections
The fuel control does far more than follow the thrust lever. Typically it:
- Limits acceleration. It adds fuel along a schedule that keeps the compressor away from surge. This is why the engine takes a few seconds to spool up from idle.
- Limits deceleration. It removes fuel slowly enough to avoid a lean flame-out.
- Holds a minimum idle. Idle is raised in icing, with anti-ice on, or on approach, so the engine can accelerate quickly for a go-around.
- Caps speed and temperature. It stops the rotor speeds and turbine temperature passing their limits.
- Manages the start. On an automatic start it opens fuel at the right rotor speed and watches for a hot or hung start; see engine start.
Worked example
Examplair 123 is on a stabilised approach with the engines at approach idle when the crew initiates a go-around. The pilot pushes the thrust levers to the go-around detent.
- The EEC reads the new lever angle and computes the target fan speed for go-around thrust in the current air temperature and pressure.
- It does not command that fuel flow at once. It follows the acceleration schedule, raising fuel flow as the core speeds up.
- Because the engine was at approach idle rather than ground idle, the core is already turning faster, and the time to reach go-around thrust is shorter.
- As the fan approaches its target, the EEC trims the fuel flow so the fan speed settles without overshoot, while watching the turbine temperature limit.
The crew sees fuel flow rising, then the fan and core speeds following, and checks that the thrust is set. Nothing in the sequence asks them to manage the fuel directly.
What pilots see and do
Pilots rarely deal with the fuel control as a separate item. They see its result in the engine indications: fuel flow, rotor speeds and turbine temperature. They use the fuel lever or master switch during start and shutdown, and in some engine failures and fires. Faults usually appear as cautions about the engine control, a loss of redundancy or an engine that does not reach the commanded thrust, each handled by the abnormal checklist.
Common misunderstandings
A frequent one is that fuel flow alone shows thrust. It does not: fuel flow for a given thrust changes with altitude, temperature and engine bleed demand. Another is that slamming the levers forward gives thrust sooner. The schedule decides the rate either way, and a smooth, prompt movement gives the same result with less chance of asymmetric thrust.
Frequently asked questions
Why does a jet engine take several seconds to spool up?
The fuel control adds fuel only as fast as the acceleration schedule allows. Adding it faster would push the compressor towards surge and the turbine towards over-temperature, so the delay is designed in, especially from idle.
What does the fuel shut-off lever actually do?
It closes a high-pressure shut-off valve in or next to the fuel metering unit, so no fuel reaches the nozzles. On most airliners it is also used to start and stop fuel flow during the engine start.
Can the pilot override the fuel control?
On a full-authority system there is no manual fuel mode; the computer always meters the fuel and protects the limits. Some older engines had a manual or reversionary mode with fewer protections, used only under abnormal procedures.
Related terms
Sources
- EASA CS-E: certification specifications for engines, engine control systems
- FAA Aviation Maintenance Technician Handbook, Powerplant: engine fuel and fuel metering systems
- FAA Airplane Flying Handbook: transition to turbopropeller and jet-powered airplanes