Logon and CPDLC connection
Also called CPDLC logon, AFN logon, Data link logon, Next data authority, Current data authority
Before pilots and controllers can exchange CPDLC messages, the aircraft must log on to the ATS unit and the unit must open a connection. The logon tells the ground who the aircraft is and matches it to its flight plan; the connection then lets one unit, the current data authority, send clearances. Connections are handed from unit to unit along the route.
What it is
CPDLC lets pilots and controllers exchange text messages instead of voice. Before the first message can be sent, two things must happen.
- Logon. The aircraft sends a short message to an air traffic services unit (ATSU) saying who it is and what data link it can use. The ground system checks this against the flight plan it holds.
- Connection. If the logon is accepted, the ground system opens a CPDLC connection to the aircraft. The aircraft accepts it automatically, and the crew sees that the unit is now connected.
On FANS 1/A aircraft, used mainly over oceans and remote areas, the logon is called an AFN logon (ATS facilities notification). On ATN B1 aircraft, used in European upper airspace, the logon is part of context management (CM). The names differ, but the idea is the same.
Why it matters
A data link that is not connected is useless when it is needed most: at an oceanic entry point, out of VHF range, where HF voice is slow and noisy. A late or failed logon can mean flying on HF only, losing reduced separation that depends on data link, or being refused a requested level or route. Getting the logon right is a short, routine task that saves a lot of trouble later.
What the logon contains
The ground system accepts a logon only when it matches a flight plan. The key data are:
| Data in the logon | Must match in the flight plan |
|---|---|
| Flight identification | Item 7, aircraft identification |
| Registration | Item 18, REG/ |
| 24-bit aircraft address | Item 18, CODE/ |
| Departure and destination | Items 13 and 16 |
Items 10a and 10b also carry the data link capability codes, such as J codes for CPDLC in item 10a and D1 for ADS-C in item 10b. If the flight plan says the aircraft has no data link, or the logon details differ from the plan, the logon is rejected.
The crew sends the logon to the unit's logon address, a four-character code published in the AIP and on en-route charts. This is not always the same as the ICAO location indicator of the centre, so check the published value.
Current and next data authority
Only one ground unit at a time can send CPDLC clearances to an aircraft. That unit is the current data authority (CDA). The next unit along the route can be named the next data authority (NDA) and open an inactive connection in advance.
A typical transfer at an FIR boundary goes like this:
- The CDA tells the aircraft which unit is next (the NDA message).
- The CDA forwards the aircraft's logon details to the next unit, so the crew does not need to log on again.
- The next unit opens its connection, which stays inactive.
- Near the boundary, the CDA ends its connection. The waiting connection becomes active and the next unit is now the CDA.
On the flight deck, the data link page shows the active centre and, where the avionics show it, the next one. The crew watches that the change actually happens at the boundary.
When to log on
The GOLD Manual gives the timing for a first logon: 10 to 25 minutes before entering airspace where data link services are provided, when the aircraft is not already connected to a previous unit. When departing from an aerodrome close to or inside that airspace, the logon may be needed before departure. Some States publish their own timing in the AIP, and some ask for the logon before an oceanic entry point so the oceanic clearance can be sent by data link. Logging on too early may be rejected because the unit does not yet hold the flight plan; logging on too late may leave the aircraft without data link at the boundary.
Worked example
A fictional flight, callsign ZZZ101, is planned from a coastal airport across an ocean FIR. Its flight plan shows CPDLC and ADS-C capability in items 10a and 10b, and the correct registration and aircraft address in item 18.
- About 20 minutes before the oceanic FIR boundary, the crew enters the oceanic centre's logon address from the chart and sends the logon.
- The logon is accepted and the centre opens a connection. The data link page shows the centre as active. The crew confirms by sending a position report or a request when the procedure calls for it.
- Six hours later, approaching the next FIR, the crew receives the NDA message. At the boundary the connection moves to the new centre without any action from the crew. The crew checks the new centre is shown as active and keeps a listening watch on the voice frequency as published.
If the transfer does not happen, the crew does not wait. It contacts the next unit by voice and, if asked, logs on to it manually.
Common mistakes
- Typing the ICAO location indicator instead of the published logon address.
- A flight identification in the FMS that differs from the filed callsign, for example an extra zero or a missing letter.
- Logging on to the wrong unit because the logon address was taken from an old chart.
- Assuming the transfer worked without checking that the new unit is shown as active.
- Treating a logon accepted message as a working connection: until the connection is open, CPDLC is not available.
Frequently asked questions
Why was my logon rejected?
Usually because the data sent does not match the filed flight plan: a different flight identification, registration or aircraft address, or a flight plan that has not reached that unit. Check the entries in the data link page and the flight plan, correct them and log on again.
Do I need to log on again at every FIR boundary?
Normally not. When the current unit forwards your address to the next one, the transfer happens automatically. You log on manually only at the first unit, after a connection failure, or when ATC asks you to.
What is the difference between a logon and a connection?
The logon is the aircraft introducing itself to the ground system. The connection is the link the ground system then opens so CPDLC messages can flow. A successful logon without a connection means you cannot yet use CPDLC.
Can two units send me CPDLC messages at once?
No. Only the current data authority can. The next data authority may hold an inactive connection, which becomes active when the current one ends.
Related terms
Sources
- ICAO Doc 10037, Global Operational Data Link (GOLD) Manual: logon, connection and transfer procedures
- ICAO Doc 4444, PANS-ATM: CPDLC establishment and transfer
- ICAO Doc 4444, PANS-ATM, Appendix 2: flight plan items 10 and 18 for data link capability