Skip to content
WeatherPerformanceFlight operations

Lapse rate

Also called Temperature lapse rate, Environmental lapse rate, Adiabatic lapse rate, DALR, SALR, ELR

Updated 29/11/20264 min read
In short

The lapse rate is the rate at which air temperature falls with height. Pilots meet three kinds: the standard rate of the ISA, the environmental rate actually measured on the day, and the adiabatic rates of a rising parcel of air. Comparing them tells you how stable the air is, where cloud will form and how far reality is from the standard atmosphere.

ISA lapse rate1.98 °C per 1,000 ft
Dry adiabaticAbout 3 °C per 1,000 ft
ISA tropopause11,000 m (36,089 ft), −56.5 °C

What it is

Climb through the lower atmosphere and the outside air temperature usually drops. The rate at which it drops with height is the lapse rate, normally given in degrees Celsius per 1,000 ft or per kilometre. A positive lapse rate means the temperature falls as you go up; a negative one means it rises, which is an inversion.

The term covers three different things, and confusing them is the commonest source of mistakes:

Lapse rateWhat it describesTypical value
ISA (standard)A fixed model of the atmosphere used for instruments and performance1.98 °C per 1,000 ft (6.5 °C per km) up to 11 km
Environmental (ELR)The real temperature profile measured on the dayVaries widely
Dry adiabatic (DALR)The cooling of an unsaturated parcel of air as it risesAbout 3 °C per 1,000 ft (9.8 °C per km)
Saturated adiabatic (SALR)The cooling of a saturated parcel as it risesTypically about 1.5 °C per 1,000 ft in warm, moist low-level air, approaching the dry rate in cold air high up

The standard lapse rate

The International Standard Atmosphere starts at 15 °C at mean sea level and cools by 6.5 °C per kilometre, close to 2 °C per 1,000 ft, up to 11,000 m (36,089 ft). Above that it holds a constant −56.5 °C, the standard tropopause and lower stratosphere.

ISA is a reference, not a forecast. Altimeters, airspeed indicators and performance charts are calibrated against it. The difference between the real temperature and the ISA temperature at your level, the ISA deviation, appears on flight plans, in performance calculations and in engine limits.

Worked example: at FL100 the ISA temperature is 15 − (10 × 1.98) ≈ −5 °C. If the outside air temperature reads +5 °C, the air is ISA +10. Warmer than standard air is less dense, so take-off and climb performance are reduced and true altitude is higher than indicated. See density altitude. In very cold air the opposite applies, and true altitude is lower than indicated, which is why cold temperature corrections exist.

Adiabatic rates

When a parcel of air rises, it moves into lower pressure and expands. Expansion cools it, even though no heat is taken away. This is adiabatic cooling. Unsaturated air cools at the dry adiabatic rate of about 3 °C per 1,000 ft. Sinking air warms at the same rate as it is compressed.

Once the parcel cools to its dew point, water vapour condenses and cloud forms. Condensation releases latent heat, so from then on the parcel cools more slowly, at the saturated adiabatic rate. That rate is not fixed. It is lowest in warm, moist air near the surface and gets closer to the dry rate in cold air higher up, where there is little vapour left to condense.

The dew point of a rising parcel also falls, but slowly, roughly 0.5 °C per 1,000 ft. The gap between temperature and dew point therefore closes by about 2.5 °C per 1,000 ft. That gives the familiar rule of thumb: the base of convective cloud lies about 400 ft above the ground for each degree of difference between surface temperature and dew point.

Lapse rate and stability

The real value of the lapse rate is what it says about stability. Compare the environmental lapse rate with the adiabatic rates of a parcel pushed upwards:

  • ELR less than SALR: absolutely stable. A rising parcel ends up colder than its surroundings and sinks back. Expect layer cloud, poor visibility in haze and smooth air, except where an inversion hides shear.
  • ELR greater than DALR: absolutely unstable. A rising parcel stays warmer than the air around it and keeps rising. Expect thermals, gusty winds and turbulence close to the ground.
  • ELR between the two: conditionally unstable. The air is stable while dry but becomes unstable once the parcel is saturated. This is the usual setting for cumulus development and, with enough moisture and lift, cumulonimbus.
Remember: a steep lapse rate means air that wants to rise. A shallow lapse rate, or an inversion, means air that resists vertical motion.
Learn it properlyMeteorology trackShort units by airline pilots and a quiz at the end of each module. Your progress is saved.See the track

Where pilots use it

You meet lapse rates in several practical places:

  • Performance: the ISA deviation, worked out from the standard lapse rate, feeds take-off, climb and cruise figures.
  • Icing: a quick estimate of the freezing level. With 12 °C at the surface and a typical lapse rate near 2 °C per 1,000 ft, 0 °C would be found near 6,000 ft, but the real level depends on the day's profile.
  • Weather briefing: forecasts and upper-air charts show the environmental profile. A steep low-level lapse rate on a summer afternoon points to convection and bumps; a strong inversion on a winter morning points to fog, haze and possible shear.

Common mistakes

The usual error is to treat 2 °C per 1,000 ft as a fact about the real air. It is the standard model only. Another is to use the dry adiabatic rate inside cloud, which overstates how fast saturated air cools. A third is to forget that the cloud-base rule works for cumulus formed by surface heating, not for frontal or layer cloud.

Frequently asked questions

Why does the temperature fall with height?

The atmosphere is heated mainly from below, by the ground warmed by the sun. Higher up the air is further from that heat source and, being at lower pressure, cooler. The exception is an inversion, where a layer of warmer air lies above colder air.

Why is the saturated rate lower than the dry rate?

When water vapour condenses it releases latent heat into the rising air. That heat offsets part of the cooling from expansion, so saturated air cools more slowly as it rises.

How do I estimate the cloud base from the METAR?

Take the difference between temperature and dew point and multiply it by about 400 ft. With 16 °C and 10 °C, the base of cumulus would be near 2,400 ft above the station. It is a rule of thumb for convective cloud only.

Is the lapse rate the same every day?

No. Only the ISA rate is fixed. The real, environmental rate changes with the air mass, the time of day and the season, and is often very different from 2 °C per 1,000 ft near the ground.

Sources

  1. ICAO Doc 7488, Manual of the ICAO Standard Atmosphere
  2. FAA Aviation Weather Handbook (FAA-H-8083-28)
  3. FAA Pilot's Handbook of Aeronautical Knowledge, chapter on weather theory
Spotted a mistake, or something missing?Suggest an edit