Skip to content
SafetyFlight operationsHuman factors

Cabin fire

Also called In-flight cabin fire, Cabin smoke and fire

Updated 26/11/20264 min read
In short

A cabin fire is a fire inside the passenger cabin, galleys or lavatories, often from electrical faults, ovens or lithium batteries in passenger devices. It is one of the most time-critical emergencies in aviation: cabin crew fight it with extinguishers and protective breathing equipment while the flight crew prepares to land as soon as possible.

PriorityFight it and land without delay
Handheld extinguishersHalon and water, typically

What it is

A cabin fire is any fire inside the occupied part of the aircraft: the passenger cabin, the galleys, the lavatories and the spaces behind the cabin panels. It ranges from a smouldering waste bin to an electrical fire hidden in the sidewall. What all cabin fires share is that they can grow quickly, fill the cabin with toxic smoke and reach systems that are hard to get at.

In flight there is nowhere to go. That is why every operator trains crews to treat any report of fire or persistent smoke as real until proven otherwise, and to act on two fronts at once: fight the fire in the cabin and get the aircraft on the ground.

Common sources

  • Galleys. Ovens, boilers and coffee makers, often with food or packaging left inside.
  • Lithium batteries. Phones, laptops, power banks and e-cigarettes can go into thermal runaway, producing intense heat, flames and dense smoke (see lithium battery fires).
  • Lavatories. Waste bins with discarded paper and, sometimes, cigarettes. Large aircraft have smoke detectors in each lavatory and an automatic extinguisher in the waste bin.
  • Electrical faults. Wiring behind panels, in-seat power, entertainment systems and lighting ballasts. These fires are often hidden at first.
  • Passenger items. Matches, lighters or other items carried against the rules.

The cabin crew response

Most operators train a team approach. Exact roles vary, but a common model uses three crew members.

RoleMain tasks
FirefighterLocates the source, fights the fire with the right extinguisher, wears protective breathing equipment
CommunicatorTells the flight crew where the fire is, what is burning, how much smoke, and what is being done; keeps updates coming
AssistantBrings more extinguishers and equipment, moves passengers away, prepares to take over from the firefighter

The firefighter puts on a smoke hood or protective breathing equipment before approaching a fire with heavy smoke (see smoke hoods and PBE). Halon, or its approved replacement, is the general-purpose agent and is safe on electrical fires. Water extinguishers are kept for burning paper and fabric, and water or other non-flammable liquid is used to cool a lithium device once the flames are out.

For a suspected hidden fire, crews feel panels with the back of the hand to find the hot spot, then follow the operator's procedure for gaining access and directing the extinguisher behind the panel. Electrical power to the affected area is removed where possible.

The flight crew response

  1. Get the facts and start the diversion. Location, source, smoke colour and density. Do not wait for the fire to be out before turning towards the nearest suitable airport.
  2. Declare an emergency. A MAYDAY gets the fastest priority and lets ATC alert rescue and firefighting services.
  3. Run the procedure. The smoke, fire or fumes checklist usually isolates likely electrical sources and, if needed, starts smoke removal. Follow the QRH or ECAM.
  4. Protect the flight deck. Keep the door closed. Put on oxygen masks and goggles at the first sign of smoke on the flight deck.
  5. Prepare for landing and evacuation. Brief the senior cabin crew member on the time available, the type of landing and whether an evacuation is expected (see emergency evacuation).
Remember: a fire that has been put out is still a reason to land. Hidden fires and lithium batteries can rekindle minutes later.
Learn it properlyFlight Operations trackShort units by airline pilots and a quiz at the end of each module. Your progress is saved.See the track

Worked example

Forty minutes after departure, a cabin crew member on Skyline 123 smells burning near row 18 and sees light smoke from a seat. The firefighter takes a Halon extinguisher and PBE, the communicator calls the flight deck, and the assistant moves nearby passengers. The source is a power bank that has slipped between seat cushions. After the flames are knocked down, the crew cools the device with water, places it in a containment bag or a container of water according to the operator's procedure, and keeps watching it.

Meanwhile the captain has already turned towards an airport 25 minutes away and declared a MAYDAY. Even with the fire apparently out, the crew lands there, because a lithium battery can flare up again and the seat structure may still be smouldering.

Prevention

Crews prevent many fires by checking galley equipment, clearing waste bins and keeping an eye on passenger devices, especially one that is hot, swollen or crushed in a seat mechanism. Passengers are told not to move a seat if a device is trapped in it, because moving it can damage the battery further.

Common mistakes

Typical errors are delaying the diversion while the cabin "investigates", opening the flight deck door to see the smoke, giving the flight crew vague or infrequent updates, and treating a knocked-down lithium fire as finished. Another is fighting the fire without protective breathing equipment in heavy smoke, which can take the firefighter out of the team in seconds.

Frequently asked questions

Should the flight crew wait until the fire is confirmed out before diverting?

No. Most guidance says to start a diversion as soon as a fire or persistent smoke is reported. A fire that seems out can rekindle, especially behind panels or in a lithium battery.

Can a water extinguisher be used on any fire?

No. Water suits burning paper, fabric and similar materials, and cooling a lithium battery after the flames are knocked down. It must not be used where live electrical equipment is involved; Halon or its approved replacement is used there.

Why should the flight deck door stay closed?

Smoke entering the flight deck can blind and incapacitate the pilots who must land the aircraft. Communication goes through the interphone, and a pilot leaves the flight deck only if the procedure calls for it.

Sources

  1. FAA Advisory Circular 120-80B, Firefighting of General and High-Energy In-Flight Fires
  2. ICAO Annex 6, Part I: hand fire extinguishers and cabin equipment
  3. EASA Air OPS, CAT.IDE.A.250: hand fire extinguishers
  4. ICAO Doc 9481, Emergency Response Guidance for Aircraft Incidents Involving Dangerous Goods
Spotted a mistake, or something missing?Suggest an edit